Treating Iron Products

Based on years of experience and research on customer needs in the oil/gas industry, Jereh has successfully developed treating iron products suitable for both standard, low-temperature and sour services, including swivel joint, plug valve, integral pup joint, integral fitting, safety valve, check valve, choke valve, hose loop and reel swivel. Maximum pressure is up to 20,000psi. Each treating iron product is conducted strict quality control and test, meeting international standards including ASTM/ASME. Each product has the only traceable number for lifecycle quality management. Tool kit and repair kit are available to suit each product for easy maintenance. Besides standard products, we can also provide customized service to meet various customer needs.

Description

Order Notice
Thank you for choosing Jereh products. To deal with your order rapidly and correctly, please provide relevant information including P/N and brief description based on the catalogue, we will deliver products to you as soon as possible.
If what you need is not shown in the catalogue, please offer additional information in reference to the following items, we will provide the most professional solution and response in the shortest period of time.
1. Product name
2. Size
3. Rated working pressure
4. Temperature rating
5. End connection/actuation/length, etc.
6. Working medium
7. Service (with or without H2S)
8. Other applicable information (such as connecting location)



After-sales Service
Jereh is consistently focused on customer needs and dedicated to exceeding customer expectations.
We believe services create values. First-class service is of equal importance to quality products.
Jereh service engineers are 24 hours standby to provide one-stop solution to achieve customer satisfaction.
• Over one hundred after-sales service engineers with rich experience and professional skills
• VIP “butler” service
• Standard and customized training





User Instruction
Jereh products are applicable for standard, low-temperature and sour gas services.
Standard Service (STD)
Temperature range: -29℃ ~121℃ /-20℉~250℉ (PU)
Application: Cementing, Fracturing, Acidizing, etc.
Low-temperature Service (STD-LT)
Temperature range: -46℃ ~121℃ /-50℉ ~250℉ (LU)
Application: Cementing, Fracturing, Acidizing, etc.
Sour Gas Service (H2S)
Temperature range: -29℃ ~121℃ /-20℉ ~250℉ (PU)
Conform to NACE MR 0175 and ISO 15156
Notes:
• Never use STD products for sour gas services to avoid equipment damage, environmental pollution or personal injury.
• Never use products of PU temperature level in services of LU temperature level to avoid seal failure or serious equipment damage.
• Never use sour gas service products for standard services to avoid excessive wear, seal failure or serious damage.
• Maximum fluid velocity is not allowed to exceed 12.2 m/s (40 ft/s); otherwise it may cause rapid erosion or even inner wall penetration.
• When ordering, please indicate relevant information, such as service condition, pressure rating and temperature range.




Operation & Maintenance
Flowline products are used for transporting high pressure fluids. Besides flow pressure, they are subject to erosion and shock of high speed flow as well as collision between pipes and surrounding objects due to pressure and equipment vibration. Therefore, please pay attention to the following instructions to extend the service life.
Operation
• Operators should take rigorous training and acquire relevant qualifications.
• Operators should be familiar with the tools to operate and maintain flowline products.
• Careful inspection is required before each use. Replace the parts in case of seal leak, broken bolt or rotation difficulty.
• Each Jereh manifold is identified by specific stainless iron strip. Users are recommended to protect it to ensure lifecylce traceability.
• Never weld or heat flowline products or components.
Maintenance
•Regular maintenance can significantly extend service life.
• Lubricate the plug valves and swivel joints before and after each use.
• After each use, thoroughly clean and maintain all surfaces exposed to fluids and seal faces.
• Each component should be regularly inspected and maintained. See details in Operation & Maintenance Manual.
Inspection, Repair and Test
• Flowline products must be regularly inspected and maintained depending on use frequency and service conditions. See details in Operation & Maintenance Manual.
• Never use parts or components not manufactured by Jereh.
• Never repair or rebuild Jereh products in a manner not recommended by Jereh.
Storage
• Keep products and repair kits away from sun, rain, sand and other foreign matters.
• Before putting into storage, make sure the fluid residue is thoroughly drained, and the interior is clean and dry.
• Try to spray rust preventive oil through the flow passage. Put protective covers on union threads and unions after coating them with rust preventive oil.

Specifications

Swivel Joints 
Style 10, Style 20, Style 30, Style 40, Style 50, Style 60, Style 80, Style 100
2″, 3″, 4″
69.0 MPa/10,000 psi, 103.5 MPa/15,000 psi, 138.0 MPa/20,000 psi
Standard Service, Low-temperature Service, Sour Gas Service
Plug Valves
Manual, Hydraulic, Manual & Hydraulic, Electric, Handwheel
1″×2″, 2″, 2″×3″, 3″
69.0 MPa/10,000 psi, 103.5 MPa/15,000 psi, 138.0 MPa/20,000 psi
Standard Service, Low-temperature Service, Sour Gas Service
Integral Pup Joints
2 ft, 3 ft, 4 ft, 5 ft, 6 ft, 8 ft, 10 ft, 300 mm, 400 mm, 500 mm, 600 mm, 700 mm, 800 mm,
1,000 mm, 1,200 mm, 1,500 mm, 1,800 mm, 2,000 mm, 2,500 mm, 3,000 mm, 4,000
mm, 5,000 mm, 6,000 mm
2″, 3″, 4″
69.0 MPa/10,000 psi, 103.5 MPa/15,000 psi, 138.0 MPa/20,000 psi
Standard Service, Low-temperature Service, Sour Gas Service
Pressure Relief Valves
Pressure Relief Valves
2″
69.0 MPa/10,000 psi, 103.5 MPa/15,000 psi, 138.0 MPa/20,000 psi
Standard Service, Low-temperature Service, Sour Gas Service
Check Valves
Top Entry Check Valves, Flapper Check Valves, Dart Check Valves
2″, 3″
69.0 MPa/10,000 psi, 103.5 MPa/15,000 psi, 138.0 MPa/20,000 psi
Standard Service, Low-temperature Service, Sour Gas Service

Choke Valves
Manual
2″, 3″
103.5 MPa/15,000 psi, 138.0 MPa/20,000 psi
Standard Service, Low-temperature Service
Integral Fittings
Tees, Laterals, Wyes, Long Radius Elbows, Elbows, Crosses, Adapters, Plug Unions
2″, 3″
69.0 MPa/10,000 psi, 103.5 MPa/15,000 psi, 138.0 MPa/20,000 psi
Standard Service, Low-temperature Service, Sour Gas Service
Hose Loops
Long Radius Type, Integral Flexible Type
2″
69.0 MPa/10,000 psi, 103.5 MPa/15,000 psi
Standard Service, Low-temperature Service, Sour Gas Service
Reel Swivels
Style U, Style L
2″, 3″
103.5 MPa/15,000 psi
Standard Service